Detail GE DM5E-DL ULTRASONIC THICKNESS GAUGE
The DM5E Basic
The DM5E Series comes in a rugged housing and ergonomically designed with a weight of just 223g, including its AA batteries, which allow up to 60 hours of operation. The basic version is specified to EN 15317 and features an LCD, which is backlit to be visible in all lighting conditions. Instrument operation is carried out with one hand via a user-friendly interface. This is a sealed, watertight and dust-proof membrane keypad, which features a minimum of function keys and arrow keys. Navigation through menus is simple and intuitive. The basic version incorporates a wide range of features including Min/ Max capture, B-Scan generation, alarms and differential thickness measurement to allow instant comparison between measured and nominal thickness.
The DM5E
Incorporates DUAL MULTI operating mode. This invaluable feature provides measuring thickness of metal through coatings. There is no need to remove the coating at the measuring point, saving time and money.
The DM5E DL
Incorporates datalogger supporting grid style data file formats. This is capable of holding up to 50, 000 readings. Files can be transferred to a PC by means of a Mini USB Com port or imported directly into Microsoft Excel through a macro. All alphanumeric data for filenames and notes is directly entered via the key pad.
Features
Manufactured by GE Inspection Technologies
0.025 to 20in Measuring Range
0.01, 0.001, 0.0001 Selectable Measuring Resolution
0.0200 to 0.7362 in/ ms Material Velocity Range
1 m/ s ( 0.0001 in/ ms)
High-Resolution Graphical LCD, 64 x 128 Pixels
2 AA Power Requirements
Instrument
Operating Principle
Ultrasonic pulse-echo method
Measurement Modes
Depends on Probe and Material, 0.60 mm to 508 mm ( 0.025” to 20.00” ) in IP to 1st BW Measurement Mode, 2.00 mm to 127.0 mm
( 0.079” to 5.00” ) in Dual-Multi Measurement Mode, the Coating Thickness Range Shall be 0.3 mm to 2.50 mm ( 0” to 0.098” ) .
Measuring Resolution
0.01 mm Default - Selectable 0.01, 0.1 mm ( 0.001” Default - Selectable 0.001, 0.01” )
Material Velocity Range 0.508 to 18.699 mm/ msec ( 0.0200 to 0.7362” / msec)
Material Velocity Resolution 1 m/ s ( 0.0001” / msec)
Units Inch or Millimeter
Calibration One-Point Cal, On-Block and Off-Block, Two-Point Cal
Pulser Excitation Pulse: Spike Pulser
Voltage: 120 V into 50 ohm Load, Using 20 MHz Oscilloscope
Receiver Bandwidth 500KHz to 12 MHz @ -3 dB
Gain Automatic Gain Control
Display Type High-Resolution Graphical LCD, 64 x 128 Pixels, 53.0 mm x 27.0 mm with Backlight and Adjustable Contrast
Update Rate 4 Hz or 8 Hz, User Selectable, 24 Hz Scan Mode Capture Rate
Thickness Value Display NORMAL View Mode 5 Digit, 10.6 mm ( 0.4” ) High
B-SCAN View Mode 5 Digit, 2.55 mm ( 0.1” ) High
Display of Last Reading Solid Filled or Hollow Digits Indicate Coupled or Uncoupled Condition
Setups 9 Standard Setups for Probes
Alarm Settings Minimum and Maximum Alarms, Range of 0.25 mm to 508 mm, 0. ( 0.010” to 20.00” )
Reading Alternates Between Solid and Hollow When Alarms Are Enabled and Violated
Power Requirements 2 “ AA” Size Batteries
Battery Life/ Operating
Time Approximately 60 Hours
Instrument Shut-0ff Selectable ALWAYS ON or AUTO OFF After 5, 10, 15, 30 Minutes of Inactivity
Language Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese
I/ O Connectors Transducer Dual Lemo 00 ( coax)
Mini-USB Mini-USB to PC
Temperature Operating -10° C to + 50° C ( + 10° F to + 120° F)
Storage -20° C to + 60° C ( -10° F to + 140° F)
Weight 223 g ( 0.597 lb) Including Batteries
Size 138 mm x 32 mm x 75 mm
Shock IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms Impulse Half Sinusoidal Wave Applied 6 Times per Axis
Sealing IEC529 / IP54, Dust Proof/ Dripping Water Proof as per IEC 529 Specifications for IP54 Classification
Tampilkan Lebih Banyak