GE DRUCK UPS II Smart Current Loop Calibrator

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
29 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail GE DRUCK UPS II Smart Current Loop Calibrator

The GE Druck UPS-II Current loop calibrator is an advanced handheld process calibrator tool. The GE Druck UPSII Loop Calibrator can power ( 24 Vdc) and read 2-wire transmitters to perform field calibrations. Output currents are adjustable to a resolution of 10 microamps in both source and transmitter simulation modes. Features: Sources and reads milliamps 24 Volt internal loop-power Powers and reads two-wire transmitters Reads and simulates dp-transmitters Fixed calibration currents Auto-stepping for handsfree calibration Auto-ramp cycling for endurance tests Fixed currents for valve stroking Includes: Spare Fuse User' s Manual Carrying Case Set of 1.5 V " AA" Alkaline Batteries ( 4) Specifications: Output Range: 0 to 21.00 mA Input Range: 0 to 21.00 mA Accuracy: 0.05% of range Resolution: 10 microamps Temperature Effect: 0.0015% / ° F ( 0.003% / ° C) Internal Loop-Power: 24 VDC stabilized. External Loop-Power: 56 VDC maximum Measurement Input: 12© including fuse Drive Capability: 900© Operating Temperature: 15° F to 120° F ( -10° C to 50° C) Battery Life: Sources 12 mA: 13 hours Measures: 64 hours Batteries: 4x 1.5V AA Batteries Loop Mismatch: Flashes " loop" Low Battery: Flashes " lobat" Over range: Flashes " EEEE" Reversed Polarity: Flashes " pol" Housing: High impact ABS Size: 3 in x 5 in x 0.83 in ( 77 mm x 124 mm x 21 mm) Weight: 9 oz ( 285 g) including batteries Fixed Steps: The calibrator can source or simulate fixed calibration currents to test or calibrate receivers and to stroke valves. Different current levels are available from the menu. 4 to 20 mA linear 4, 8, 12, 16, 20 mA; 0 to 20 mA linear 0, 5, 10, 15, 20 mA; 4 to 20 mA sq.rt ( flow) 4, 5, 8, 13, 20 mA; 0 to 20 mA sq.rt ( flow) 0, 1.25, 5, 11.25, 20 mA; 4 to 20 mA 3.8, 4, 4.2, 12, 19, 20, 21 mA. Output currents can be changed manually or automatically. The time between steps is 10 seconds in the auto-stepping mode. In the valve mode, auto-stepping will be: 3.8, 4, 4.2 or 19, 20, 21 mA Ramping: The calibrator can source or simulate with high resolution a continuous up/ down cycle between 4 and 20 mA or 0 and 20 mA. The travel time between limits is 60 seconds. Reading in Percentage: The calibrator can display readings in percentage of a 4 to 20 mA or 0 to 20 mA span and can also read or simulate dP-transmitters directly in percentage of flow.
Tampilkan Lebih Banyak