Detail AMETEK HPC500 7 Bar/ 300 Psi Pressure Calibrator
JOFRA HPC500 / HPC502 calibrators feature deadweight tester accuracy in a modern digital package. The HPC is available as an independent calibrator or in one of 6 ready-for-test systems that are complete and equipped to meet any need for pressure calibration.
The HPC500 may be used in a very broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems. The JOFRA HPC500 calibrators introduce a new generation of AMETEK handheld pressure calibrators. This series has been designed to meet high accuracy pressure calibration applications and faciliate your tasks. The HPC offers features such as user configurable information display, 15 different pressure units, transmitter supply, mA input, % error calculation, voltage measurement, serial communication, and external pressure module capability. The accuracy of the HPC500 calibrators is specified in % of reading to ensure an even better accuracy and wider applicable pressure range. The HPC is temperature compensated from 0 to 50º C / 32 to 122º F for on-site operation. It is a truly superior pressure calibrator for laboratory and field use, bringing laboratory accuracy into the field.
The JOFRA APM series of pressure modules extends the application base of the HPC calibrators by allowing calibrations in additional ranges. The APM modules are compatible with several other JOFRA calibrators.
Includes:
HPC500 calibrator
Traceable calibration certificate ( NIST) with pressure and vacuum performance
4 x 1.5 volt batteries
Adapter to 1/ 4” NPT male from 1/ 8” BSP male
Adapter 1/ 4” BSP female from 1/ 8” BSP male
1/ 8” sealed gasket / washer type
Test leads: red and black
Hand strap with clip
User manual
Specifications:
Engineering units ( built-in) : User selectable: 15 units
Pressure accuracy ambient temp. ( 18 to 28° C / 65 to 82° F) : Pressure ± 350 mbar / 5 psi: ± 0.05% F.S. Vacuum: ± 0.10% F.S.
Pressure accuracy ambient temp. ( 0 to 50° C / 32 to 122° F) : Pressure ± 350 mbar / 5 psi: ± 0.10% F.S. Vacuum: ± 0.05% F.S.
Display: LCD: Graphical ( with light) . Display resolution: 5 digits. Display update: 3 times per second
RS232 communication interface: Connector: LEMO. Serial: 0-5 VDC, 9600 baud, 8 data, no parity, 1 stop. Protocol: ASCII command language
Input / output ( 18 to 28° C / 65 to 82° F) : mA range: 0 to 24 mA. mA accuracy: ± 0.015% RDG + 2 ¼ A. Transmitter supply: 24 VDC ± 10% . Voltage measurement: 0 to 30 VDC. Voltage accuracy: ± 0.015% RDG + 2mV. HART® resistor: 250 © . RTD range ( ohms) : 84 to 140 © . RTD accuracy: ± 0.015% RDG + 0.02 © . RTD range ( temperature) : -40 to 105º C / -40 to 220º F. RTC accuracy @ 0º C/ 32º F ( temperature) : ± 0.10º C / 0.18º F. Peak hold capture: 50 milliseconds. Switch test input: 5V ( < 1mA) .
Media compatibility: Nickel plated brass and 316 stainless steel. Environmental: Operating temperature: -10 to 50° C / 14 to 122° F. Storage temperature: -20 to 60° C / -4 to 140° F. Ingress protection rating: IP54
Pressure connection: All calibrators: 1/ 8” BSP female
Pressure overload: Overload alarm: “ OL” in display at approx. + 20% F.S.
Power supply: Battery: 4 x 1.5 VDC Alkaline. Battery type: AA, LR6, MN1500, AM3. Battery lifetime: Typically more than 35 hours. Low battery indicator: Yes
Instrument dimensions ( LxWxH) : Calibrator: 201x99x50 mm / 8.3x3.9x2.0 in. HPC500 weight ( incl. battery) : 635 g / 22.4 oz. Calibrator, shipping: 243x180x80 mm/ 9.6x7.1x3.1 in. Calibrator weight, shipping: 1.1 kg / 39.5 oz
Miscellaneous: Compliance: Compliance: EN 61326 : 2006 and CISPR 11, Edition 5.0 - 2009 Class “ B” .
Tampilkan Lebih Banyak