Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

HIOKI 3286-20 Clamp On Power Hi-Tester

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
3 kali
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HIOKI 3286-20 Clamp On Power Hi-Tester

The 3286-20 provides the following 2 types of power factor measurement. If the waveform includes harmonic distortion, there will be a difference between the two measurement values, and the method must be selected accordingly. Power factor derived by phase discrimination ( cos ¦ ) : 1¦ Power Factor meter and 3¦ Power Factor meter mode From the phase information for the fundamental frequency component, cos ¦ is calculated. This is suitable for assessing the quality of a power supply. Power factor ( effective value power factor) derived from effective power ¦ apparent power: 1¦ Power meter mode This is calculated from the power value including harmonic components ( effective power ¦ apparent power) . This is suitable for evaluating the performance of standalone load equipment and similar cases. * It is not possible to calculate the effective power factor of a three-phase line. The 3286-20' s three-phase power measurement method calculates and displays the power values for a sine wave input at 50/ 60 Hz, assuming it is balanced and there is no distortion. Accurate measurement is not possible on a three-phase line if it is not balanced, for example when controlled by an inverter or thyristor. Features Use as a single-phase power meter or power factor meter ( 3kW to 660kW) Simple checking of three-phase lines ( 6kW to 1200kW range) Check power supply fluctuations 1000A, 1000 Hz, peak and harmonic measurement True RMS ( effective value) display method Optional printer ( 9442 Printer) Specification: Measurement Lines: Single-phase/ two-wires, Three-phase/ three-wires ( balanced load only) Measurement Items: Voltage, current, voltage/ current peak, effective/ reactive/ apparent power( Single-phase or 3-phase) , power factor, reactivity, phase angle, frequency, phase detection( 3-phase) , voltage/ current harmonic levels( up to 20th) Measurement Ranges: Voltage: 150.0 V to 600 V, 3 ranges Current: 20.00 to 1000 A, 3 ranges Power: 3.000 kW to 1200 kW, 18 combination patterns Note: 3-phase power is calculated and displayed on the basis of a balanced, 50/ 60 Hz, sine wave input. For apparent power and reactive power, the unit of watts in the above table is replaced by VA and var respectively. Basic Accuracy: Power/ single-phase: ± 2.3 % rdg. ± 5 dgt., Power/ 3-phase: ± 3.0 % rdg. ± 10 dgt. ( at balanced load) Voltage/ Current Accuracy: Voltage: ± 1.0 % rdg. ± 3 dgt., Current: ± 1.3 % rdg. ± 3 dgt. ( at 45 to 66 Hz) Frequency characteristics ( at AC current / voltage) : AC current : 45 to 1 kHz AC voltage : 30 to 1 kHz Other functions : Phase detection, Record ( Max. value/ Min. value) , Battery capacity display, Data hold, Auto power off, Data output ( RS-232C interface by optical insulating coupler) Display Update Rate: NORMAL: approx. 1 time/ sec, SLOW: 1 time/ 3-sec, HARM meas.: approx. 1 time/ 2-sec Power Supply: 6LR61 alkaline battery × 1 ( continuous operation max. 25 hours) , 6F22 manganese battery × 1 ( continuous operation max. 10 hours) Core jaw dia.: Ø 55 mm( 2.17 in) or 80 mm ( 3.15 in) × 20 mm ( 0.79 in) busbar Dimensions: 100 mm( 3.94 in) W × 287 mm( 11.3 in) H × 39 mm( 1.54 in) D Weight: 650 g ( 22.6 oz) Accessories: 9635 VOLTAGE CORD ( 1) , 9245 CARRYING CASE, ( 1) , Hand strap ( 1)
Tampilkan Lebih Banyak